Capsule rubbing and splitting, this is very headache, and it is also often encountered when soft capsule equipment is running. need to be treated carefully. This phenomenon generally occurs due to the following reasons:
1. The reason for the capsule itself, the difference between the capsule cap and the capsule body is too large. The bladder needs to be replaced.
2. Too much powder remains on the module. Module cleaning is required.
3. When installing the module, the upper and lower molds are not aligned, re-align the module. Until the adjustment lever can automatically fall.
4. In fact, it is also related to the particle size of the powder. In the process of talking with others, others have also said that there is a reason. I haven't confirmed it specifically. If there is indeed such a reason, then this item should be added in the verification, whether the particle size can cause the phenomenon of insertion and splitting, if it is confirmed that this phenomenon does occur, then consider whether to replace the screen when granulating.
5. Whether the thimble is too high at the closure of the capsule and cap.
6. To solve the phenomenon of insertion and splitting, there is a way to try, shorten the distance between the upper die and the top plate, of course, the distance is not too short. The principle is: before the insertion and splitting have occurred, it is said to be locked. This method does work, and it's the most I've used. Once before, I found that there was no way to solve the plug and split. I almost replaced the whole batch of capsule shells that came into the factory. Finally, I used this method to solve the problem of insertion and splitting.
Daily maintenance, maintenance and precautions of soft capsule equipment:
1. The vibration machinery of the soft capsule equipment should always be checked for the tightening of the screws in various parts. If there is any looseness, it should be tightened in time to prevent failure and damage.
2. Plexiglass parts (workbench, medicine board) should avoid direct sunlight and close to high temperature, and heavy objects should not be placed. The medicine board must be placed vertically or flat to avoid deformation and damage.
3. The electrical enclosure and body must be grounded to ensure safety, and the power supply is cut off after work. .
4. After working every day, the residual medicine on the machine and in the mold hole should be cleaned to keep the whole machine clean and hygienic, and avoid washing the host with water. If the mold on the machine needs to be cleaned, the fixing screw can be loosened, and it can be taken off, which is easy to install.